Fixed Gas & Flame Detection

Featured MSA FL3100H UV/Infared Flame Detector

FL500 UV/IR Flame Detector

The FL500 UV/IR Flame Detector monitors for radiation emitted by a flame in both the ultraviolet (UV) and infrared (IR) spectral ranges. This UV/IR combination provides a fast response time and increased false alarm immunity against sources of radiation for reliable protection.
view details
Featured MSA General Monitors S5000 Gas Monitor with X-Cell gas sensor

General Monitors S5000 Gas Monitor

The General Monitors S5000 Gas Monitor is the ultimate gas detector for extreme environments needing to detect oxygen, toxic and combustible gases. It operates over a wide temperature range using a variety of gas sensing technologies. XCell® gas sensors with TruCal® technology extends calibration cycles up to 18 months. Dual sensing capability doubles the sensing power.
view details
Featured MSA Senscient ELDS Open Path Gas Detector

Senscient ELDS™ Open Path Gas Detector

The Senscient ELDS laser-based open path gas detector is available for a wide range of toxic and flammable gases. The Senscient ELDS uses 'SimuGas' self-testing to eliminate employees entering hazardous areas for gas checks. Nuisance false alarms are virtually eliminated with its breakthrough Harmonic Fingerprint processing.
view details
Featured MSA FL4000H Multi-spectrum Infared Flame Detector mounted on metal bracket

FL4000H Multi-spectrum IR Flame Detector

The FL4000H is an advanced multi-spectrum infrared (MSIR) flame detector that provides superior false alarm immunity with the widest field of view. The FL4000H employs a multi-spectral optical IR sensing array with a sophisticated Neural Network Technology (NNT) system to reliably discriminate between actual flames and the vast majority of false alarm sources. The FL4000H detects typical fires such as alcohol, n-heptane, gasoline, jet fuels and hydrocarbons. It can also see through dense smoke produced by diesel, rubber, plastics and lube oil fires.
view details
Featured S4000CH Combustible Gas Detector

S4000CH Combustible Gas Detector

The S4000CH Intelligent Sensor is a microprocessor-based transmitter designed for use with General Monitors industry-leading catalytic bead sensors. It features one person calibration and virtually self-calibrates by simply activating a magnetic switch and applying gas. It monitors combustible gases and vapors within the lower explosive limit (LEL) and provides status indication and alarm outputs. Complies with ANSI/ISA 12.13.01-2000 performance requirements for combustible gas detectors.
view details
Featured MSA IR400 Point Infared Gas Detector

IR400 Point IR Gas Detector

The IR400 Infrared (IR) Point Detector is a hydrocarbon gas detector that continuously monitors combustible gases and vapors within the lower explosive limit (LEL) and provides alarm indication. It features an industry-leading response time of ≤ 3 seconds, even with a splash guard installed. All electronics are contained within an explosion-proof housing so that the IR400's detector information can be processed locally. Configurations with analog output, Modbus and HART are also available.
view details
Featured MSA S4000TH Hydrogen Sulphide Gas Detector Unit - front view

S4000TH H2S Gas Detector

The S4000TH Intelligent Gas Sensor is a microprocessor-based transmitter designed for use with General Monitors' thin film metal oxide semiconductor (TFMOS) sensors to detect H2S gas. The unit features one person calibration and can virtually self-calibrate by simply activating a magnetic switch and applying gas. It detects hydrogen sulfide in 0-20 ppm, 0-50 ppm or 0-100 parts per million (ppm) levels over a wide temperature range. 
view details

SB100 Ultrasonic Bump Tester

The SB100 is a hand-held battery-operated rechargeable ultrasonic tester designed to bump test General Monitors ultrasonic gas leak detectors. The SB100 is useful for quick tests where physical access to the ultrasonic gas detector can be difficult. The unit can be used to bump test up to 18 meters away from the detector in Class 1, Div 1&2 hazardous areas.
view details

FL3100H UV/IR Flame Detector

The FL3100H is an Ultraviolet / Infrared flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It monitors in both the ultraviolet (UV) and infrared (IR) spectral ranges, making it highly immune to false alarms. Configurations with dual Modbus and HART are available. Modbus and HART data can be used for predictive maintenance. The flame detector's electronics are integral within its explosion-proof housing, allowing detector information to be processed locally.
view details

Zero Two Series Gas and Flame Detection System

Modular system offering the widest range of control cards for use in an integrated fire and/or gas detection system. The Zero Two Series system can monitor any combination of the following: combustible gas, H2S, toxic gas, ultrasonic, oxygen deficiency and flame detection. In addition, its open architecture allows the system to accommodate other sensing devices for tasks such as smoke detection, heat detection and manual call points. 
view details

TA102A Single Channel Combustible Trip Amplifier Module

The TA102A is a single-channel Combustible Gas Trip Amplifier Module designed for use with one General Monitors intelligent transmitter to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through a front panel interface (mode / select switch and digital display). A digital display indicates fault codes and set up options. Other features include: LED indications of status, as well as both open collector and relay outputs for fault, low alarm and high alarm.
view details

4802A Zero Two Series Control Module for Combustible Applications

The 4802A is a single channel Combustible Gas Control Module that has been designed for use with our proven catalytic bead sensors. It is designed to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through the front panel interface. A digital display indicates gas concentration, fault codes, calibration cues and setup options. Other features: LED indications of status, as well as open collector and relay outputs.
view details

610A Four Channel Combustible Gas Monitor

The 610A is a system for continuously monitoring combustible gas (hydrocarbon) concentrations in four locations. The system consists of four General Monitors remote catalytic bead sensing assemblies and a solid-state controller. The controller features four independent channels, each having its own circuitry. The 610A features a digital display of gas concentrations in % LEL (0-99% lower explosive limit) for each channel.
view details

Catalytic Bead Sensors

The General Monitors catalytic bead gas sensors are well known for their sensitivity, reliability and longevity and make them the first choice for most users of the catalytic oxidation gas detection principle. Every component is manufactured in-house to ensure optimum performance. Careful matching of the active and reference elements ("beads") result in a sensor that has negligible zero drift with respect to changes in humidity, pressure, and temperature.
view details

IR5500 Open Path Infrared Gas Detector

The IR5500 is an open path infrared (IR) gas detector that continuously monitors for flammable gas leaks over large open areas. It monitors in both the LEL-m and ppm-m ranges to detect both small and large leaks. The IR5500 offers the benefits of early detection with its high sensitivity to gas concentrations at the ppm levels.  This feature allows it to alarm faster than an LEL-only detector. Digital display and adjustable mounting arms ensure easy alignment. Factory calibrated for low-maintenance operation.
view details

580A Dual-Channel Combustible Gas Monitor

The 580A is a compact, highly-versatile system for continuously monitoring combustible gas (hydrocarbon) concentrations in two locations. The system consists of two remote catalytic sensing assemblies and a solid-state controller. The controller automatically displays the higher reading channel on a digital display, scaled from 0-100% LEL (lower explosive limit). Manual override switching permits readout of the low channel at any time.
view details

Catalytic Bead Accessories

General Monitors offers a wide variety of accessories for our catalytic bead gas sensors.
view details

FL3100H-H2 UV/IR Flame Detector for Hydrogen Applications

The FL3100H-Hydrogen is an Ultraviolet / Infrared flame detector designed specifically to detect hydrogen (H2) fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects H2 fires by monitoring in both the ultraviolet (UV) and infrared (IR) spectral ranges, making it highly immune to false alarms. Configurations with dual Modbus and HART are available. Modbus and HART data can be used for predictive maintenance. The flame detector's electronics are integral within its explosion-proof housing, allowing detector information to be processed at the point of detection.
view details

TA202A Single Channel H2S Trip Amplifier Module

The TA202A is a single-channel H2S Trip Amplifier Module for use with our H2S Intelligent Sensors. It is designed to monitor H2S in parts per million (ppm) levels and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through front panel interface (mode / select switch and digital display).
view details

2280A Four Channel H2S Gas Monitor

The 2280A is a system for continuously monitoring H2S gas concentrations in four locations. The system consists of up to four remote mounted sensors and a solid state controller. The controller consists of four independent channels, each having its own circuitry. With a digital display, the 2280A shows hydrogen sulfide gas concentrations in ppm (parts per million) in the ranges of 0-20, 0-50, or 0-99 ppm for each channel.
view details
Product Comparison Queue (0) Compare Products